Precise prediction of size of a foldable capsular vitreous body via computerized three-dimensional ocular reconstruction in severe retinal detachment.


ABSTRACT:

Background

This study aimed to precisely predict the size and silicone oil injection of a foldable capsular vitreous body (FCVB) via computerized three-dimensional (3D) ocular reconstruction in the treatment of severe retinal detachment in China.

Methods

The 3D software Unigraphics NX was applied to determine the volume of the inner cavity with 16-30 mm axial length, assigning the anterior and posterior chambers, the FCVB sizes, and the silicone oil injection volume, and modeling the data between the axial length and the FCVB size. In clinical practice, IOL Master was applied to accurately measure the axial length of the contralateral healthy eye to anchor the anterior-posterior and horizontal diameters of the operated eye in horizontal position CT, and compared with the mod