Dynamic dosing for continuous renal replacement therapy: Service evaluation of the safety and effectiveness of titrating dose to biochemistry.


ABSTRACT:

Introduction

Continuous renal replacement therapy (CRRT) dose is usually fixed and primarily weight-based. Whilst this is safe, theoretically, underdosing or overdosing may occur in those requiring acute versus maintenance CRRT respectively. We have developed a dynamic dosing protocol for CRRT which individualises and updates dosing according to biochemistry. Here we describe the protocol and compare it to a fixed dose protocol to evaluate its safety and effectiveness.

Methods

We conducted a service evaluation of this novel protocol using data from consecutive non-COVID-19 admissions receiving CRRT within Barts Health NHS trust, United Kingdom (UK). Fifty admissions using the dynamic protocol were compared to historically collected data from 108 admissions who used the fixed

SUBMITTER: Eldridge JC 

PROVIDER: S-EPMC11421270 | biostudies-literature | 2024 Feb

REPOSITORIES: biostudies-literature