Correlation of Acetabular Cup Placement Angles Between an Artificial Intelligence-Powered System Using a Smartphone and Human Measurements.


ABSTRACT:

Background

An automated measurement system for the placement angles of acetabular cup in total hip arthroplasty prostheses was developed utilizing artificial intelligence (AI) algorithms. The AI-powered system enables immediate measurement by capturing an anteroposterior pelvic X-ray through a smartphone camera.

Methods

While developing the AI-powered measurement system, we trained AI utilizing 100 labeled anteroposterior pelvic X-rays to recognize the hip joint and 483 labeled anteroposterior pelvic X-rays to identify anatomical landmarks and the acetabular cup. To validate the AI-powered system, we measured the acetabular cup placement angles of 126 unlabeled post-total hip arthroplasty anteroposterior pelvic X-rays with both the AI-powered system and conventional measurem