Power saw noise levels during steel stud cutting tasks on commercial construction sites: a tool characterization from a worker exposure standpoint.
Ontology highlight
ABSTRACT: Construction framers who cut and install steel studs as part of their daily tasks are exposed to hazardous noise levels during their work shift in large part due to the power saws they use to cut steel studs. This investigation characterized the sound pressure levels of power saws used to cut steel studs on active construction sites. Further, the length of time it took to cut various studs on a construction site was investigated to understand worker exposure times to saw noise. In general, power saws used on the study sites to cut steel studs had a mean A-weighted equivalent continuous sound pressure level (LAeq) of 107.2 dB and a C-weighted peak sound pressure level (LCpeak) of 120.1 dB. Three of the saws-the chopsaw, the cut-off saw, and the grinder-had similar noise levels, whereas the
SUBMITTER: Schutt D
PROVIDER: S-EPMC11427544 | biostudies-literature | 2024 Sep
REPOSITORIES: biostudies-literature