Label-Free Detection of Waterborne Pathogens Using an All-Solid-State Laser-Induced Graphene Potentiometric Ion Flux Immunosensor.
Ontology highlight
ABSTRACT: Waterborne pathogens are harmful microorganisms transmitted through water sources. Early and rapid pathogen detection is important for preventing illnesses and implementing stringent water safety measures to minimize the risk of contamination. This work introduces a miniaturized all-solid-state potentiometric ion flux immunosensor for the rapid and label-free detection of waterborne pathogens. A screen-printed silver/silver chloride electrode coated with a reference electrode membrane and polyurethane as an all-solid-state reference electrode was combined with a solid-state contact ion-selective electrode (ISE). An all-solid-state ISE was constructed on laser-induced graphene by coating it with a cationic marker and a carboxylated poly(vinyl chloride)-based membrane for immobilizing antibo
SUBMITTER: Preechakasedkit P
PROVIDER: S-EPMC11428094 | biostudies-literature | 2024 Sep
REPOSITORIES: biostudies-literature