ABSTRACT: Background
The management of hemodynamically unstable pelvic ring injuries necessitates surgical intervention, often involving procedures such as external fixation and percutaneous screw placement. Given the infrequent performance of these procedures, regular training is imperative to ensure readiness for emergencies. Our pre- post simulation study aimed to adapt and validate a realistic simulation model for stabilizing unstable pelvic ring injuries, facilitating participants' knowledge retention and procedural confidence enhancement.Methods
A standardized simulator of an unstable pelvic ring utilizing synthetic pelvic bones featuring complete disruption of the symphysis and sacroiliac joint was developed. Trauma surgeons of a level one academic hospital were invited to per
SUBMITTER: Klingebiel FK
PROVIDER: S-EPMC11428295 | biostudies-literature | 2024 Sep
REPOSITORIES: biostudies-literature