Development of optimal indoor air disinfection and ventilation protocols for airborne infectious diseases.


ABSTRACT: Since the COVID-19 pandemic, there has been persistent emphasis on the importance of indoor air disinfection and ventilation in isolation units in the hospital environment. Nevertheless, no optimal and concrete disinfection protocol has been proposed to inactivate the viruses as quickly as possible. In this study, we experimentally evaluated various ventilation and disinfection protocols based on the combination of negative-pressure ventilation, ultraviolet (UV) light illumination, and Hypochlorous acid (HOCl) spray against three active virus species in a 3.5 cubic meters isolation unit. This small-size unit has gained attention during the pandemic due to the high demand for compact mobile laboratory systems capable of rapid disease diagnosis. In accordance with the WHO laboratory biosafet

SUBMITTER: Park J 

PROVIDER: S-EPMC11444385 | biostudies-literature | 2024