ABSTRACT: Background
Although pulse oximetry technology, which is considered the standard of care to ensure optimum oxygenation, is indispensable in clinical practice, especially in the detection of hypoxemia, it has some limitations in the detection of hyperoxemia. Oxygen Reserve Index can provide clinicians with a crucial pathway in detecting and preventing hyperoxia, noninvasively. Our aim in this study is to determine the hyperoxia detection ability of ORi and to investigate the effectiveness of ORi and SpO2-guided FiO2 titration in preventing hyperoxia.Methods
This prospective randomized study was conducted in the operating theater of Health Sciences University İzmir Tepecik Training and Research Hospital from September 1, 2020, to December 1, 2022. Patient
SUBMITTER: Sarıtas PU
PROVIDER: S-EPMC11457429 | biostudies-literature | 2024 Oct
REPOSITORIES: biostudies-literature