Determination of a robust headspace GC-MS/MS method for analysis of ethyl alcohol and acetaldehyde: clinical application to pharmacokinetics study.


ABSTRACT: Due to the forensic aspects of drinking and exposure to toxic substances, more sophisticated quantitative technology is needed to quantify the concentration of ethyl alcohol and acetaldehyde in the blood. In this study, we developed a headspace gas chromatography tandem mass spectrometry method that could simultaneously detect ethyl alcohol and acetaldehyde in human plasma. Through a simple preparation process, ethyl alcohol and acetaldehyde were quickly detected within 4 min, and a lower limit of quantification (LLOQ) (20 and 0.2 µg/mL) was obtained; these results confirmed the suitability of the system. According to Food and Drug Administration guidelines, the linearity (correlation coefficient > 0.9996), intraday and intraday accuracy, precision, and both short- and long-term stability

SUBMITTER: Oh HA 

PROVIDER: S-EPMC11458342 | biostudies-literature | 2024 Sep

REPOSITORIES: biostudies-literature