Ablation therapy following unsuccessful electrical cardioversion in patients with persistent atrial fibrillation.


ABSTRACT: Electrical cardioversion (ECV) a widely utilized intervention for persistent atrial fibrillation (AF) aimed at restoring sinus rhythm. However, ECV can be ineffective, raising questions about subsequent treatment options. This study aimed to compare the outcomes of non-ablation therapy versus ablation therapy following unsuccessful ECV. A total of 125 consecutive patients with persistent AF who underwent unsuccessful ECV between November 2017 and August 2023 was included in this retrospective analysis. Of these, 51.2% received only medical therapy (non-ablation therapy group, n = 64), while 48.8% underwent AF ablation (ablation therapy group, n = 61). Various ablation methods were employed, including catheter and thoracoscopic ablation. Ablation therapy was associated with significantly better AF-free survival compared to non-ablation therapy [hazard ratio (HR), 0.37; 95% confidence interval (CI) 0.22-0.61; p < 0.01]. There was no difference of AF-free survival between catheter ablation and thoracoscopic ablation groups (HR 0.79, 95% CI 0.34-1.83; p = 0.58). AF duration > 5 year (HR 1.51; 95% CI 0.930-2.437; p = 0.10), BMI ≤ 25 kg/m2 (HR 1.61; 95% CI 1.004-2.581; p = 0.05) and diabetes (HR 2.38; 95% CI 0.902-6.266; p = 0.08) were considerable as predictor of AF recurrence. Ablation therapy following unsuccessful ECV was associated with maintaining sinus rhythm, regardless of the specific ablation method utilized.

SUBMITTER: Lee HJ 

PROVIDER: S-EPMC11458593 | biostudies-literature | 2024 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Ablation therapy following unsuccessful electrical cardioversion in patients with persistent atrial fibrillation.

Lee Hyo Jin HJ   Lee Su Hyun SH   Kim Juwon J   Kim Ju Youn JY   Park Seung-Jung SJ   Park Kyoung-Min KM   On Young Keun YK  

Scientific reports 20241007 1


Electrical cardioversion (ECV) a widely utilized intervention for persistent atrial fibrillation (AF) aimed at restoring sinus rhythm. However, ECV can be ineffective, raising questions about subsequent treatment options. This study aimed to compare the outcomes of non-ablation therapy versus ablation therapy following unsuccessful ECV. A total of 125 consecutive patients with persistent AF who underwent unsuccessful ECV between November 2017 and August 2023 was included in this retrospective an  ...[more]

Similar Datasets

| S-EPMC9205203 | biostudies-literature
| S-EPMC5968006 | biostudies-literature
| S-EPMC12432329 | biostudies-literature
| S-EPMC10130175 | biostudies-literature