Arthroscopic Measurements Predict Knee Chondral Lesion Size More Accurately Than Magnetic Resonance Imaging, and Mechanism of Injury Influences Ability of Either Technique to Predict Graft Size.


ABSTRACT:

Purpose

To compare osteochondral defect size measurements and characteristics across magnetic resonance imaging (MRI) and arthroscopy and at the time of osteochondral allograft (OCA) transplantation or autologous chondrocyte implantation (ACI).

Methods

Patients who underwent ACI and OCA transplantation at a single institution between 2015 and 2019 were retrospectively identified. Patients were excluded if they had severe osteoarthritis, MRI scans were not available for review, surgical records did not include defect sizing necessary for analysis, or operative reports were not available. Osteochondral lesion characteristics including size were collected preoperatively by MRI and arthroscopy and at the time of definitive open surgical intervention. Subgroup analysis was perfor

SUBMITTER: Hanna AJ 

PROVIDER: S-EPMC11480797 | biostudies-literature | 2024 Aug

REPOSITORIES: biostudies-literature