Unknown

Dataset Information

An SPR-Based In Situ Methane Sensor for the Aqueous and Gas Phase.


ABSTRACT: This paper presents a fast, low-cost, precise methane sensor based on refractive index changes in a cryptophane A (CryptA)-doped polystyrene membrane. For the realization of this sensor, we built a surface plasmon resonance sensor with a refractive index resolution of 4.31 × 10-6 and investigated the optimal membrane thickness, i.e., a polymer layer of sufficient sensitivity with the lowest response time. For a membrane thickness of 760 nm, a limit of detection of 135 ppm and a response time constant of 45 s were found. Despite a comparable refractive index resolution and a higher CryptA content, the limit of detection is 3 orders of magnitude larger than that of a reported prototype. The sensor is capable of quantifying methane in the gas or aqueous phase. However, temperature,

SUBMITTER: Estelmann A 

PROVIDER: S-EPMC11485097 | biostudies-literature | 2024 Oct

REPOSITORIES: biostudies-literature