Effect of different CPAP levels on ultrasound-assessed lung aeration and gas exchange in neonates.


ABSTRACT:

Background

Respiratory distress syndrome (RDS) and transient tachypnoea (TTN) are the two commonest neonatal respiratory disorders. The optimal continuous positive airway pressure (CPAP) to treat them is unknown. We aim to clarify the effect of different CPAP levels on lung aeration and gas exchange in patients with RDS and TTN.

Methods

Prospective, observational, pragmatic, physiological cohort study. CPAP was sequentially increased from 4 to 6 and 8 cmH2O and backwards, with interposed wash-out periods. Lung aeration was assessed with a validated neonatal lung ultrasound score. Gas exchange was non-invasively evaluated with transcutaneous monitoring. Ultrasound score and PtcO2/FiO2 ratio were the co-primary outcomes. PtcCO2 and o