Unknown

Dataset Information

Comparison of outcomes for transjugular intrahepatic portosystemic shunt creation: Viatorr versus Fluency versus a bare stent/Fluency stent combination.


ABSTRACT:

Purpose

To compare clinical outcomes of transjugular intrahepatic portosystemic shunt (TIPS) created with the single covered-uncovered stent (Viatorr TIPS Endoprosthesis) versus covered stent (Fluency) versus a combination of covered and uncovered stent.

Materials and methods

From May 2016 and July 2019, a total of 180 liver cirrhosis patients with recurrent variceal bleeding underwent TIPS creation with single covered-uncovered stent (n = 63) or covered stent (n = 41) or a covered and uncovered stent combination (n = 76). Shunt dysfunction, rebleeding, overt hepatic encephalopathy and mortality was estimated using the Kaplan-Meier method and compared with the log-rank test.

Results

The difference of baseline characteristics among these three groups were not significa

SUBMITTER: Li W 

PROVIDER: S-EPMC11489360 | biostudies-literature | 2024 Oct

REPOSITORIES: biostudies-literature