Clinical implementation of advanced respiratory monitoring with esophageal pressure and electrical impedance tomography: results from an international survey and focus group discussion.


ABSTRACT:

Background

Popularity of electrical impedance tomography (EIT) and esophageal pressure (Pes) monitoring in the ICU is increasing, but there is uncertainty regarding their bedside use within a personalized ventilation strategy. We aimed to gather insights about the current experiences and perceived role of these physiological monitoring techniques, and to identify barriers and facilitators/solutions for EIT and Pes implementation.

Methods

Qualitative study involving (1) a survey targeted at ICU clinicians with interest in advanced respiratory monitoring and (2) an expert focus group discussion. The survey was shared via international networks and personal communication. An in-person discussion session on barriers, facilitators/solutions for EIT implementation was organized wi

SUBMITTER: Wisse JJ 

PROVIDER: S-EPMC11493933 | biostudies-literature | 2024 Oct

REPOSITORIES: biostudies-literature