Unknown

Dataset Information

Development of a UHPLC-MS/MS Method for the Determination of Moxidectin in Rat Plasma and Its Application in Pharmacokinetics.


ABSTRACT: The aim of the present study was to establish a simple and reliable ultra-high-performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method and apply it for the determination of pharmacokinetics of moxidectin-loaded microspheres (MOX-MS) in rats. Plasma samples were processed using a simplified liquid-liquid extraction method and were separated using an Agilent Zorbax Eclipse Plus C18 column (50 mm × 2.1 mm, 1.8 μm) with a mobile phase consisting of a 10 mM ammonium formate solution with 0.1% formic acid (A) and acetonitrile (B) at a flow rate of 0.4 mL/min for 5 min. Avermectin B1a was used as an internal standard (IS). The sample was injected at a volume of 10 μL with a column temperature of 35 °C and detected in a positive ion mode. A good linear response across the c

SUBMITTER: Zhang H 

PROVIDER: S-EPMC11510379 | biostudies-literature | 2024 Oct

REPOSITORIES: biostudies-literature