ABSTRACT: Running biomechanics have traditionally been analysed in laboratory settings, but this may not reflect natural running gait. Wearable technology has the potential to enable precise monitoring of running gait beyond the laboratory. This study aimed to evaluate the analytical validity and intra-session reliability of temporal running gait outcomes measured by the ViMove2 wearable system in healthy adults. Seventy-four healthy adults (43 males, 31 females, aged 18-55 years) wore the inertial device, ViMove2 on the tibia. Participants ran on a treadmill for one minute at various speeds (8, 10, 12, 14km/hr), completed in a standardised shoe (Saucony Guide Runner). Running gait was measured with the ViMove2 wearable and 3D motion capture (Vicon). Temporal running gait outcomes included ground co