Adaptive Pressure Control-Continuous Mandatory Ventilation Versus Volume Control-Continuous Mandatory Ventilation: Factors Associated With Initiation, Maintenance, and Adjustment.


ABSTRACT:

Background

Adaptive pressure control-continuous mandatory ventilation (APC-CMV) is a frequently utilized ventilator mode in ICU settings. This analysis compared APC-CMV and traditional volume control-continuous mandatory ventilation (VC-CMV) mode, describing factors associated with initiation, maintenance, and changes in settings of each mode.

Methods

We analyzed ventilator data from a retrospective electronic health record data set collected as part of a quality improvement project in a single academic ICU. The majority ventilator mode was defined as the mode comprising the highest proportion of mechanical ventilation time. Multivariable logistic regression was used to identify variables associated with initial and majority APC-CMV or VC-CMV modes. Wilcoxon rank-sum tests w

SUBMITTER: Tran LN 

PROVIDER: S-EPMC11572997 | biostudies-literature | 2024 Nov