Methods for determining optimal positive end-expiratory pressure in patients undergoing invasive mechanical ventilation: a scoping review.


ABSTRACT:

Purpose

There is significant variability in the application of positive end-expiratory pressure (PEEP) in patients undergoing invasive mechanical ventilation. There are numerous studies assessing methods of determining optimal PEEP, but many methods, patient populations, and study settings lack high-quality evidence. Guidelines make no recommendations about the use of a specific method because of equipoise and lack of high-quality evidence. We conducted a scoping review to determine which methods of determining optimal PEEP have been studied and what gaps exist in the literature.

Source

We searched five databases for primary research reports studying methods of determining optimal PEEP among adults undergoing invasive mechanical ventilation. Data abstracted consisted of the

SUBMITTER: Edginton S 