Highly sensitive voltammetric determination of the fungicide fenhexamid using a cost-effective and disposable pencil graphite electrode.
Ontology highlight
ABSTRACT: A differential pulse voltammetric (DPV) method is proposed for the highly sensitive determination of fenhexamid (FHX) based on both electrooxidation and electroreduction processes using a disposable and cost-effective pencil graphite electrode (PGE). The electrochemical oxidation and reduction mechanisms of FHX at the PGE were elucidated by recording cyclic voltammograms at various pH values of Britton-Robinson buffer (BRB) solutions at a scan rate of 50 mV s-1 and different scan rate values in the range 10-400 mV s-1 at selected pH of BRB (pH 2.0). Differential pulse voltammograms recorded under optimized conditions revealed an oxidation peak of FHX around + 0.65 V and a reduction peak of FHX around + 0.45 V. The DPV analysis of FHX revealed two linear ranges: 0.001-
SUBMITTER: Ersan T
PROVIDER: S-EPMC11607022 | biostudies-literature | 2024 Nov
REPOSITORIES: biostudies-literature
ACCESS DATA