Comparative analysis of triplanar Chevron osteotomy (TCO) and Chevron osteotomy (CO) for treating mild to moderate hallux valgus via computer simulation and 3D printing: An observational study.
Ontology highlight
ABSTRACT: Hallux valgus (HV) deformity, which is characterized by lateral deviation and pronation of the metatarsophalangeal joint, demonstrates complex 3-dimensional challenges, thus prompting the development of various surgical approaches, including traditional Chevron osteotomy (CO) and novel triplanar Chevron osteotomy (TCO). The objective of this study is to determine TCO at various tilt angles by employing 3D printing for ex vivo osteotomy angle simulations and computer modeling to correct deformities across 3 planes, thus aiming to enhance surgical outcomes by preserving or even increasing the length of the first metatarsal and thereby overcoming the limitations of CO. In this study, we collected and analyzed non-weight-bearing CT data from 55 patients (61 feet) with mild-to-moderate hallux v
SUBMITTER: Cao J
PROVIDER: S-EPMC11608690 | biostudies-literature | 2024 Nov
REPOSITORIES: biostudies-literature
ACCESS DATA