Ontology highlight
ABSTRACT: Objectives
This study aimed to identify the cyclical "on-off" flow of pulmonary microcirculation during inspiration and expiration by sidestream dark field imaging (SDF) technology in vivo and investigate the effects of volume status and driving pressure on cyclical "on-off" flow of microcirculation.Methods
24 ARDS-modeled rabbits were randomly divided into high-driving pressure group (HDP group) and low-driving pressure group (LDP group). Lung microcirculation measurements were performed using the SDF microscope at two timepoints (T1 CVP 2-4 mmHg, T2 CVP 8-10 mmHg). From T1 to T2, 10 ml/kg saline was infused to increase CVP. The cyclical "on-off" pulmonary microcirculation was quantitatively assessed by the change of microcirculation between expiration and inspiration.
SUBMITTER: Yuan S
PROVIDER: S-EPMC11618265 | biostudies-literature | 2024 Dec
REPOSITORIES: biostudies-literature