Investigation of interfractional range variation owing to anatomical changes with beam directions based on water equivalent thickness in proton therapy for pancreatic cancer.
Ontology highlight
ABSTRACT: To assess the interfractional anatomical range variations (ARVs) with beam directions and their impact on dose distribution in intensity modulated proton therapy, we analyzed water equivalent thickness (WET) from 10 patients with pancreatic cancer. The distributions of the interfractional WET difference ($\Delta{\mathrm{WET}}^{\theta }$) across 360° were visualized using polar histograms. Interfractional ARVs were evaluated using the mean absolute error and ΔWET pass rate, indicating the percentage of $\Delta \mathrm{WE}{\mathrm{T}}^{\theta }$ < thresholds. The impact on dose distribution in proton therapy was evaluated based on two treatment plans for 40 Gy(RBE)/5 fractions: 'Plan A', using two beam angles, in which the target was closest to the body surface among four perpendicular direc
SUBMITTER: Kikkawa Y
PROVIDER: S-EPMC11629986 | biostudies-literature | 2024 Dec
REPOSITORIES: biostudies-literature
ACCESS DATA