Implementation of a Cardiovascular Implantable Electronic Device Heart Failure Prediction Tool-Guided Management Pathway.


ABSTRACT: Cardiovascular implantable electronic devices (CIEDs) monitor physiologic variables that could identify subacute heart failure (HF) decompensation and impending HF hospitalization. One such algorithm uses measurements from the previous 30 days of CIED remote monitoring data to predict low-, medium-, or high-probability of HF hospitalization in the next 30 days. We sought to understand how to prospectively implement the use of such algorithms in routine HF care. From January 18, 2024 to April 19, 2024, HF risk categories were predicted from scheduled remote transmissions every 30 days and from unscheduled transmissions for all patients at 2 distinct cardiology clinics. Clinicians contacted and assessed patients at high risk regarding symptoms and then provided an empiric 3-day diuretic inte

SUBMITTER: Kratka A 

PROVIDER: S-EPMC11645256 | biostudies-literature | 2024 Dec