Unknown

Dataset Information

Design dimensions of electrocutaneous warning stimulation patterns in workplace safety devices.


ABSTRACT: Warning of workers in dangerous situations is crucial. With the aim of deriving practical parameters for an electrocutaneous warning stimulation, we explore the design dimensions of pulse intervals, amplitudes, and locations of electrocutaneous stimulation in a study on healthy volunteers. Using biphasic rectangular current pulses on the upper right arm of 81 healthy participants, they evaluated temporal perception with varying intervals, ranging from 200 ms down to 0.5 ms, categorizing it as 'Individual pulses', 'Pulsating', 'Vibrating', or 'Continuous'. Next, we tested nine amplitude levels. Participants rated the perceived amplitude on a scale from 1 to 9 after a training phase. Finally, we presented five consecutive stimulation pulses in a pseudo-random order at eight electrode pair po

SUBMITTER: Dolker EM 

PROVIDER: S-EPMC11649102 | biostudies-literature | 2024

REPOSITORIES: biostudies-literature