Non-invasive removal of a misplaced and knotted guidewire during ultrasound-guided central venous catheter insertion in a hybrid operating room: a case report.


ABSTRACT:

Background

The standard of care for placement of a central venous catheter (CVC) includes a real-time ultrasound (US)-guided technique. We describe a rare case in which the guidewire penetrated the posterior wall of the vessel, forming a knot, which precluded simple removal. This occurred despite the procedure being performed under real-time US guidance. The guidewire was eventually removed under fluoroscopic guidance in a hybrid operation room.

Case presentation

An 89-year-old male underwent the placement of a CVC in the left internal jugular vein. During the US-guided procedure, the guidewire penetrated the posterior wall of the vessel and formed a knot, which impeded simple removal. This was confirmed by radiologic imaging. Using a short sheath and a push-pull technique,