Dosimetric comparison and evaluation of different convergence modes in nasopharyngeal carcinoma using VMAT treatment deliveries.


ABSTRACT:

Background

This study investigates the impact of convergence mode (CM) in Eclipse (Varian Medical Systems) on the quality and complexity of volumetric modulated arc therapy (VMAT) plans for nasopharyngeal carcinoma (NPC) patients.

Methods

We retrospectively analyzed data from 21 NPC patients. For each patient, three VMAT plans with different CM settings (Off, On, and Extended) were created using identical optimization objectives. Plan quality was assessed using indices such as the conformity index (CI) and homogeneity index (HI), as well as evaluating target coverage and sparing of organs at risk (OARs). Complexity was measured by metrics including average leaf pair opening (ALPO), modulation complexity scores for VMAT (MCSv), monitor units (MUs), and optimization time. Dosi