Predicting per- and polyfluoroalkyl substances removal in pilot-scale granular activated carbon adsorbers from rapid small-scale column tests.
Ontology highlight
ABSTRACT: Per- and polyfluoroalkyl substances (PFAS) occur widely in drinking water, and consumption of contaminated drinking water is an important human exposure route. Granular activated carbon (GAC) adsorption can effectively remove PFAS from water. To support the design of GAC treatment systems, a rapid bench-scale testing procedure and scale-up approach are needed to assess the effects of GAC type, background water matrix, and empty bed contact time (EBCT) on GAC use rates. The overarching goal of this study was to predict PFAS breakthrough curves obtained at the pilot-scale from rapid small-scale column test (RSSCT) data. The scale-up protocol was developed for pilot data obtained with coagulated/settled surface water (TOC = 2.3 mg/L), three GACs, and two EBCTs. Between 7 and 11 PFAS breakthro
SUBMITTER: Hopkins ZR
PROVIDER: S-EPMC11706541 | biostudies-literature | 2024 Mar-Apr
REPOSITORIES: biostudies-literature
ACCESS DATA