Imprecision nutrition? Intraindividual variability of glucose responses to duplicate presented meals in adults without diabetes.


ABSTRACT:

Background

Continuous glucose monitors (CGMs) are used to characterize postprandial glucose responses and provide personalized dietary advice to minimize glucose excursions. The efficacy of such advice depends on reliable glucose responses.

Objectives

To explore within-subject variability of CGM responses to duplicate presented meals in an inpatient setting.

Methods

CGM data were collected from two inpatient feeding studies in 30 participants without diabetes, capturing 1189 responses to duplicate meals presented ∼1 wk apart from four dietary patterns. One study used two different CGMs (Abbott Freestyle Libre Pro and Dexcom G4 Platinum) whereas the other study used only Dexcom. We calculated the incremental area under the curve (iAUC) for glucose for each 2-h postmeal

SUBMITTER: Hengist A 

PROVIDER: S-EPMC11747189 | biostudies-literature | 2025 Jan