Perfusate Liver Arginase 1 Levels After End-Ischemic Machine Perfusion Are Associated with Early Allograft Dysfunction.


ABSTRACT: Background/Objectives: The rising use of liver grafts from donation after circulatory death (DCD) has been enabled by advances in normothermic regional perfusion (NRP) and machine perfusion (MP) technologies. We aimed to identify predictive biomarkers in DCD grafts subjected to NRP, followed by randomization to either normothermic machine perfusion (NMP) or dual hypothermic oxygenated perfusion (D-HOPE). Methods: Among 57 DCD donors, 32 liver grafts were transplanted, and recipients were monitored for one week post-transplant. Biomarkers linked with oxidative stress, hepatic injury, mitochondrial dysfunction, inflammation, regeneration, and autophagy were measured during NRP, end-ischemic MP, and one week post-transplant. Results: Arginase-1 (ARG-1) levels were consist

SUBMITTER: Basta G 

PROVIDER: S-EPMC11760452 | biostudies-literature | 2025 Jan