Predicting High-Grade Acute Urinary Toxicity and Lower Gastrointestinal Toxicity After Postoperative Volumetric Modulated Arc Therapy for Cervical and Endometrial Cancer Using a Normal Tissue Complication Probability Model.
Ontology highlight
ABSTRACT: (1) Background: Volumetric modulated arc therapy (VMAT) can deliver more accurate dose distribution and reduce radiotherapy-induced toxicities for postoperative cervical and endometrial cancer. This study aims to retrospectively analyze the relationship between dosimetric parameters of organs at risk (OARs) and acute toxicities and provide suggestions for the dose constraints. (2) Methods: A total of 164 postoperative cervical and endometrial cancer patients were retrospectively analyzed, and the endpoints were grade ≥ 2 acute urinary toxicity (AUT) and acute lower gastrointestinal toxicity (ALGIT). The normal tissue complication probability (NTCP) model was established using the logistic regression model. Restricted cubic spline (RCS) curves were used to explore the association between do