Electro-Conductive Modification of Polyvinylidene Fluoride Membrane for Electrified Wastewater Treatment: Optimization and Antifouling Performance.


ABSTRACT: Electro-conductive membranes coupled with a low-voltage electric field can enhance pollutant removal and mitigate membrane fouling, demonstrating significant potential for electrified wastewater treatment. However, efficient fabrication of conductive membranes poses challenges. An in situ oxidative polymerization approach was applied to prepare PVDF-based conductive membranes (PVDF-CMs) and response surface methodology (RSM) was adopted to optimize modification conditions enhancing membrane performance. The anti-fouling property of the conductive membranes was analyzed using model pollutants. The results indicate that when the concentrations of the pyrrole, BVIMBF4, and FeCl3·6H2O are 0.9 mol/L, 4.8 mmol, and 0.8 mol/L, respectively, the electrical resistan

SUBMITTER: Shi J 

PROVIDER: S-EPMC11767159 | biostudies-literature | 2024 Dec

REPOSITORIES: biostudies-literature