ABSTRACT: Background
The role of radiolytic oxygen consumption for the in-vitro "Ultra-High Dose Rate" (UHDR) sparing and in-vivo FLASH effect is subject to active debate, but data on key dependencies such as the radiation quality are lacking.Purpose
The influence of "dose-averaged Linear Energy Transfer" (LETd) and dose rate on radiolytic oxygen consumption was investigated by monitoring the oxygen concentration during irradiation with electrons, protons, helium, carbon, and oxygen ions at UHDR and "Standard Dose Rates" (SDR).Methods
Sealed "Bovine Serum Albumin" (BSA) 5% samples were exposed to 15 Gy of electrons and protons, and for the first time helium, carbon, and oxygen ions with LETd values of 1, 5.4, 14.4, 65, and 100.3 keV/µm, respectively, delivered at mean dose ra