Evaluation of a deformable image registration algorithm for image-guided thermal ablation of liver tumors on clinically acquired MR-temperature maps.


ABSTRACT:

Background

Quantitative real-time MRI-based temperature mapping techniques are hampered by abdominal motion. Intrascan motion can be reduced by rapid acquisition sequences such as 2D echo planar imaging (EPI), and inter-scan organ displacement can be compensated by image processing such as optical flow (OF) algorithms. However, motion field estimation can be seriously affected by local variation of signal intensity on magnitude images inherent to tissue heating, potentially leading to erroneous temperature estimates.

Purpose

This study aims to characterize, in the context of clinical MRI-guided microwave ablation (MWA), a novel deformable image registration (DIR) algorithm that enhances the generation of thermal maps aligned to a reference position, a critical step for calcu