Unknown

Dataset Information

Decoupled level and flow rate control of a two-tank system in beverage production: A comparative analysis of Fuzzy-PID and GA-PID for minimum time operation.


ABSTRACT: Due to the nonlinear characteristics of the valves and the interactions between the controlled variables, designing a control system for coupled tanks is a difficult task. This paper deals with the comparative study between Fuzzy-PID and GA-PID controllers for decoupling level and flow rate control of two tank systems for beverage factories with minimum time optimal operation. In most process control industries, each process requires multiple control variables. Here two input two output (TITO) systems are considered highly interacting multivariable control systems. The decoupling control scheme (Pre-compensator (dynamic) decoupling) is used to reduce the correlation between the controlled and manipulated variables by diagonalizing the system. The two independent SISO systems are further co

SUBMITTER: Kassie TD 

PROVIDER: S-EPMC11798464 | biostudies-literature | 2025

REPOSITORIES: biostudies-literature