Unknown

Dataset Information

Endoscopic closure of esophageal, gastric, jejunal, and rectopelvic fistulas with cardiac septal occluder devices: a case series.


ABSTRACT:

Background and aims

Treating GI fistulas and anastomotic leaks is a challenge. Traditionally, these adverse events have been treated with conservative measures or surgical interventions, both of which have been associated with high rates of morbidity. Although endoscopic techniques are available and commonly minimally invasive, their success can be variable and oftentimes require repeat interventions. Cardiac septal occluder (CSO) devices have emerged as an alternative for managing these complex GI fistulas and anastomotic leaks after the more conservative endoscopic options fail.

Methods

Before the introduction of the CSO device into the body, a CSO delivery system must first be created. After integrating this system with an endoscope, argon plasma coagulation is used on ea

SUBMITTER: Cohen EM 

PROVIDER: S-EPMC11853373 | biostudies-literature | 2025 Feb

REPOSITORIES: biostudies-literature