Postselection shifts the transition frequency of helium in an atomic beam.
Ontology highlight
ABSTRACT: Postselecting output states can effectively amplify weak signals in measurements. However, the postselection (PS) effect may also introduce unintended biases in precision measurements. Here, we investigate the influence of PS in the precision spectroscopy of the 23S - 23P transition of helium (4He) using an atomic beam. We directly observe that PS based on atomic positions causes a shift in the measured transition frequency, amounting to approximately -55 kHz. After accounting for this PS shift, we obtain a corrected frequency of 276,764,094,712.45 ± 0.86 kHz for the 23S1 - 23P0 transition. Combining this result with existing data for 3He, we derive a value for the difference
SUBMITTER: Wen JL
PROVIDER: S-EPMC11870057 | biostudies-literature | 2025 Feb
REPOSITORIES: biostudies-literature
ACCESS DATA