ABSTRACT: Background
Two weeks of continuous glucose monitoring (CGM) sampling with >70% CGM use is recommended to accurately reflect 90 days of glycemic metrics. However, minimum sampling duration for CGM use <70% is not well studied. We investigated the minimum duration of CGM sampling required for each CGM metric to achieve representative glycemic outcomes for <70% CGM use over 90 days.Methods
Ninety days of CGM data were collected in 336 real-life CGM users with type 1 diabetes. CGM data were grouped in 5% increments of CGM use (45%-95%) over 90 days. For each CGM metric and each CGM use category, the correlation between the summary statistic calculated using each sampling period and all 90 days of data was determined using the squared value of the Spearmen correlation coefficien