Unknown

Dataset Information

Conventional one-handed compared to two-handed endoscopic ear surgery using an endoscope holder: a single center study.


ABSTRACT:

Introduction

One-handedness is a challenge in conventional endoscopic ear surgery (EES). We present results on the first-ever application of the passive endoscope holder 'Endofix exo' (Co. AKTORmed GmbH, Neutraubling, Germany) in EES, which enables two-handed surgery.

Methods

This two-sided study compares cut-suture time, operating time, postoperative complications, graft take rates, hearing results and quality of life in patients who underwent first stage tympanoplasty due to tympanic membrane perforation with intact ossicular chain conditions. 25 patients received classic EES (EES-, mean age: 28 ± 21 years) and 15 received EES with the passive holder (EES+, mean age: 48 ± 21 years).

Results

Mean operating times (EES-: 96 ± 38 (SD) min; EES+: 107 ± 33 min), cut-sutur

SUBMITTER: Muller C 

PROVIDER: S-EPMC11890327 | biostudies-literature | 2025 Mar

REPOSITORIES: biostudies-literature