Calibration of PurpleAir low-cost particulate matter sensors: model development for air quality under high relative humidity conditions.


ABSTRACT: The primary source of measurement error from widely used particulate matter (PM) PurpleAir sensors is ambient relative humidity (RH). Recently, the US EPA developed a national correction model for PM2.5 concentrations measured by PurpleAir sensors (Barkjohn model). However, their study included few sites in the southeastern US, the most humid region of the country. To provide high-quality spatial and temporal data and inform community exposure risks in this area, our study developed and evaluated PurpleAir correction models for use in the warm-humid climate zones of the US. We used hourly PurpleAir data and hourly reference-grade PM2.5 data from the EPA Air Quality System database from January 2021 to August 2023. Compared with the Barkjohn model, we found improved pe

SUBMITTER: Mathieu-Campbell ME 

PROVIDER: S-EPMC11900072 | biostudies-literature | 2024

REPOSITORIES: biostudies-literature