Planning Automation for Treatment Techniques Comparison and Robustness Analysis: Tangential Intensity Modulated Radiation Therapy and Volumetric Modulated Arc Therapy for Whole Breast Irradiation.


ABSTRACT:

Purpose

This study evaluates the use of the mCycle automated planning system integrated into the Monaco Treatment Planning System for step-and-shoot intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) in whole breast irradiation (WBI). The aim was to assess whether automation can standardize plan quality across a diverse patient cohort and compare dosimetric outcomes and robustness of the 2 techniques against setup errors and anatomical variations.

Methods and materials

A total of 65 patients with breast cancer who underwent postoperative WBI were selected for the study. Treatment plans were generated using mCycle, which employs multicriteria optimization with no manual intervention. Two automated planning techniques-IMRT and VMAT-were im

SUBMITTER: Marrazzo L 

PROVIDER: S-EPMC11910076 | biostudies-literature | 2025 Mar