Comparing the mechanical energetics of walking among individuals with unilateral transfemoral limb loss using socket and osseointegrated prosthetic interfaces.


ABSTRACT: Osseointegration (OI), or bone-anchoring, of a prosthesis is a transformative procedure for addressing issues of socket fit among individuals with lower limb loss. Mechanically, the removal of the socket interface substantially alters the transmission of load and the flow of energy through the prosthetic limb. Here, we compared the mechanical energetics of walking between socket and OI interfaces using biomechanical data and custom models of 8 service members pre- and ~24-months post-OI. Relative to a socket interface, an OI interface shifted loads toward the intact limb, which increased collision losses, while the net mechanical work of both the prosthetic and intact limbs remained minimal for both interfaces. At the joint level, despite the removal of the socket interface potentially sav

SUBMITTER: Golyski PR 

PROVIDER: S-EPMC11928544 | biostudies-literature | 2025 Mar