Unknown

Dataset Information

Effects of different reduction patterns on stress distribution in patients with intertrochanteric fractures with intramedullary nail fixation: a finite element analysis.


ABSTRACT:

Objective

Positive medial cortical support is a reliable fracture reduction pattern, but existing research on its use is mainly qualitative. We conducted this finite element analysis study to quantitatively evaluate the usefulness of positive cortical support for intertrochanteric fracture reduction.

Methods

Twenty-five models of intramedullary nail fixation for AO type 31-A1.2 intertrochanteric fractures subjected to different reduction patterns were established. The peak von Mises stress at the femoral fracture surface, proximal intersection of the intramedullary nail, and distal intersection of the intramedullary nail, as well as the maximum fracture displacement, were determined by finite element analysis under the three working conditions of standing, walking, and walki

SUBMITTER: Zhu J 

PROVIDER: S-EPMC11936888 | biostudies-literature | 2025

REPOSITORIES: biostudies-literature