Quantitative Study of Spodumene by Time-of-Flight Secondary Ion Mass Spectrometry (tof-SIMS).
Ontology highlight
ABSTRACT: In this paper, the quantitative feasibility of time-of-flight secondary ion mass spectrometry (tof-SIMS) for major and minor elements in spodumene was evaluated in terms of calibration method with a matrix-matched or non-matrix-matched standard and an internal standard element using Al or Si. The matrix-matched standard calibration method was studied using spodumene 503R as the external standard and unknown sample, with signal intensities collected under positive ion mode using 100 µm of raster size. The sensitivities of Li, Na, Al, Si, Mn, and Fe were obtained by applying the sample-standard bracketing method, and the corresponding concentrations were given as the division of signal intensities by sensitivities. It was found that there were no significant differences between concentration
SUBMITTER: Tan X
PROVIDER: S-EPMC11990334 | biostudies-literature | 2025 Mar
REPOSITORIES: biostudies-literature
ACCESS DATA