ABSTRACT: Background and objectives
There are limited randomized studies on patients undergoing multi-vessel percutaneous coronary intervention (PCI) comparing the outcomes between stent thickness and polymer types. To compare the clinical outcomes of thick biodegradable polymer-based biolimus A9-eluting stents (BESs) and thin durable polymer-based zotarolimus-eluting stents (ZESs) in patients undergoing multi-vessel PCI.Methods
A total of 936 patients who underwent multi-vessel coronary artery stenting were randomly assigned to the BES (n=472) or ZES (n=464) groups. The primary endpoint was 2-year major adverse cardiac events (MACEs), a composite of all-cause death, myocardial infarction (MI), and any revascularization at the 2-year follow-up.Results
Fifty-two (11.2%) of 472 patients in BES group and 50 (10.9%) of the 464 patients in ZES group met the 2-year primary endpoint of MACE (hazard ratio, 1.00; 90% confidence interval, 0.72, 1.38; p=0.994). All-cause death (BES vs. ZES: 2.8% vs. 2.7%, p=0.758), MI (2.1% vs. 2.6%, p=0.483), and repeat revascularization (6.7% vs. 6.9%, p=0.876) were not significantly different between the 2 groups. Although there was no significant outcome difference in any subgroup analysis, the technical failure rate leading to the use of other stents was higher in BES than in ZES (3.2% vs. 0.9%, p=0.023).Conclusions
In patients who underwent multi-vessel PCI, BES and ZES showed comparable 2-year clinical outcomes. However, BES was not established to demonstrate non-inferiority to ZES in terms of the incidence of the primary endpoint at the 2-year. The technical success rate of the index PCI with the assigned stent was higher for thinner ZES.Trial registration
ClinicalTrials.gov Identifier: NCT01947439.
SUBMITTER: Lee CH
PROVIDER: S-EPMC12088991 | biostudies-literature | 2025 May
REPOSITORIES: biostudies-literature

Korean circulation journal 20250217 5
<h4>Background and objectives</h4>There are limited randomized studies on patients undergoing multi-vessel percutaneous coronary intervention (PCI) comparing the outcomes between stent thickness and polymer types. To compare the clinical outcomes of thick biodegradable polymer-based biolimus A9-eluting stents (BESs) and thin durable polymer-based zotarolimus-eluting stents (ZESs) in patients undergoing multi-vessel PCI.<h4>Methods</h4>A total of 936 patients who underwent multi-vessel coronary a ...[more]