ABSTRACT: Objective
Hypoglossal nerve stimulation (HNS) is an increasingly used therapy. However, not all patients undergoing HNS implantation benefit from the treatment, making an improved patient selection a priority. This study investigates whether backscattered ultrasonographic imaging (BUI) can predict the response to HNS therapy.Study design
Cross-sectional study.Setting
Secondary and tertiary hospital.Methods
In this multicenter cross-sectional study, we recruited patients who had undergone HNS implantation during their scheduled follow-up consultation. HNS therapy parameters were collected. Standardized submental ultrasonographic examination and home sleep apnea testing were performed. The primary outcome was assessing the response to HNS therapy using ultraso