Correction of Physiological Artifacts in Multi-Echo fMRI Data-Evaluation of Possible RETROICOR Implementations.
Ontology highlight
ABSTRACT: The study evaluates the efficacy of RETROICOR (Retrospective Image Correction) in mitigating physiological artifacts within multi-echo (ME) fMRI data. Two RETROICOR implementations were compared: applying corrections to individual echoes (RTC_ind) versus composite multi-echo data (RTC_comp). Data from 50 healthy participants were collected using diverse acquisition parameters, including multiband acceleration factors and varying flip angles, on a Siemens Prisma 3T scanner. Key metrics such as temporal signal-to-noise ratio (tSNR), signal fluctuation sensitivity (SFS), and variance of residuals demonstrated improved data quality in both RETROICOR models, particularly in moderately accelerated runs (multiband factors 4 and 6) with lower flip angles (45°). Differences between RTC_ind and RTC_