Unknown

Dataset Information

An international survey of diffusion and perfusion magnetic resonance imaging implementation in the head and neck.


ABSTRACT:

Objective

The goal of this international survey was to understand how diffusion (DWI) and perfusion imaging (PWI) are being applied to clinical head and neck imaging.

Methods and materials

An online questionnaire focusing on acquisition, clinical indications, analysis, and reporting of qualitative DWI (QlDWI), quantitative DWI (QnDWI) and dynamic contrast-enhanced PWI (DCE-PWI) in the head and neck was circulated to members of the American Society of Head and Neck Radiology (ASHNR) and European Society of Head and Neck Radiology (ESHNR) over a 3-month period. Descriptive statistics and group comparisons were calculated with SPSS® v27.

Results

There were 294 unique respondents (17.6% response rate) from 256 institutions (182 ESHNR, 74 ASHNR). DWI was routinely acquired

SUBMITTER: Connor S 

PROVIDER: S-EPMC12226617 | biostudies-literature | 2025 Feb