Unknown

Dataset Information

Successful Ethanol Infusion of Vein of Marshall With Bridge Collateral Using the Double-Balloon Technique Incorporating a Wedged Berman Catheter.


ABSTRACT: We describe a novel double-balloon technique incorporating a wedged Berman catheter to manage distal collateral drainage from the vein of Marshall (VOM) via a bridge collateral to the great cardiac vein, thereby enabling effective ethanol infusion. This technique may represent a viable alternative for anatomically challenging VOM ethanol infusion cases.

SUBMITTER: Kasai Y 

PROVIDER: S-EPMC12280225 | biostudies-literature | 2025 Aug

REPOSITORIES: biostudies-literature