Upscaling of thermoacoustic-Stirling duplex cryocoolers based on resonance tube coupling.


ABSTRACT: To address the critical need for energy-efficient and environmentally sustainable cooling technologies, the thermoacoustic-Stirling duplex cryocooler (TSDC) offers a promising solution due to its high efficiency and versatile applications. However, the limited cooling capacity of individual TSDCs poses a significant challenge for practical implementation, necessitating system upscaling. To enhance power density and performance, we optimized a resonance tube-coupled TSDC by incorporating a coiled resonance tube and developing an active displacer modeling approach. A prototype with optimized dimensions was constructed and tested, demonstrating a linear relationship between cooling power at 130 K and input heating power, with a maximum cooling capacity of 380 W achieved at an exergy efficienc

SUBMITTER: Wei L 

PROVIDER: S-EPMC12362697 | biostudies-literature | 2025 Sep

REPOSITORIES: biostudies-literature